Item | Description | Refer to | ||||
---|---|---|---|---|---|---|
Queue Settings | Use this window to set the initial values of the queue folder printing settings. The settings in this window will be applied to all corresponding queue folders unless the settings are changed in the [Job Settings] window. | Queue Properties Window | ||||
Spot Color Settings | A list of the preset spot color library names (Roland spot colors, DIC, TOYO, PANTONE). With VersaWorks, spot colors other than Roland spot colors are replaced with CMYK for printing. You can create, delete, and duplicate spot color libraries, and can assign and convert spot colors. | Using Spot Colors | ||||
Special Color Settings | Displays a list of special color library names. Detects the specific colors in a job by color value (RGB or CMYK) and replaces them with color values defined in VersaWorks. | Using Special Colors | ||||
Printer Color Match Settings | Used to adjust output color variations that occur on the same printer or between multiple printers that are the same model. | Obtaining a Stable Output Color | ||||
Simulation Profile Management | Configures a profile to match the output colors of different printer models. | Customizing the Color Settings | ||||
Nearest Color Finder Library | The Nearest Color Finder Library list appears. You can delete unnecessary results. | Managing the Nearest Color Finder Library | ||||
Preferences | This is composed of 5 tabs (General, Measurement Instrument, Roland@NET, Multiple Printer Support, and Linking), and configures settings for the entire application. | |||||
General | Configures general settings such as Language and Unit and Preview. | |||||
Language and Unit | You can set the language and unit to display in VersaWorks. After the language is changed, you have to restart VersaWorks. | Setting the Language, Font Size, and Unit | ||||
Language | Select the display language from [English], [Chinese_Simplified], [Chinese_Traditional], [French], [German], [Italian], [Japanese], [Korean], [Portuguese], [Spanish], [Russian], [Turkish], or [Arabic]. Default value: Language selected at the time of installation |
|||||
Unit | Select the display unit from mm, cm, and inch. Default value: mm |
|||||
Font Size | Select Large, Standard, or Small. Default value: Standard |
|||||
Preview | You can select the quality of the preview image from High Quality, Standard Quality, and Low Quality. Default value: Standard Quality |
Different Monitor Colors and Printed Colors | ||||
Quality | ||||||
Enable Monitor Proofing | When this check box is selected, the colors in the preview display will be closer to those in the printed materials. Default value: Off |
|||||
RGB Profile | Use the [AdobeRGB1998.icc], [Roland_SignRGB.icc], [sRGB Color Space Profile.icm], and [Roland_DG_WideGamut_RGB.icc] RGB profiles to display the preview with colors that closely approximate the actual output colors. | |||||
Input Folder | You can display the queue folders (A - E) in the layout area. Default value: On |
Displaying the Queue Folder Name in the Layout Window | ||||
Show Queue Identifier in Layout Window | ||||||
Processing Speed Settings | When multiple printers are connected to VersaWorks, you can set the number of RIP processing operations to perform simultaneously. Default value: 1 (when only one printer is registered) or 2 (when multiple printers are registered) |
Setting the Number of Simultaneous RIP Processing Operations | ||||
Max. # of concurrent RIP processes | ||||||
Print Options | Sets the print count and the warning when the amount of remaining ink is low. | |||||
Configure Advanced Print Settings | When this check box is cleared, the specified job is printed only once at all times without specifying the print count. Default value: On |
Printing Only Once at All Times | ||||
Display warning according to the amount of ink remaining when printing | When this check box is selected, you can configure the settings so that a warning is displayed if the amount of remaining ink is low when you attempt to print. Default value: On |
Setting Warning Displays According to the Amount of Remaining Ink | ||||
Adjust Amount of Memory Used in RIP | Adjusts the amount of the computer's memory that is used during processing by the RIP, output, and job importing. Default value: 1024 MB |
Avoiding Memory Shortages in the Application | ||||
Measurement Instrument | Sets the type of measurement instrument to use in For Color Charts, For Spot and Special Colors, and For Printer Color Matching. | Setting the Measurement Instrument to Use | ||||
For Color Charts |
Specifies the model to use when creating and registering new media. Select from [X-Rite i1Pro / Pro 2 / Pro 3], [X-Rite i1Pro 3 Plus], [X-Rite i1iO / iO 2 / iO 3], [X-Rite i1iO 3 Plus], [X-Rite i1iSis], [Barbieri Spectro LFP qb], and [Barbieri Spectro pad]. Default value: [X-Rite i1Pro / Pro 2 / Pro 3] |
|||||
For Spot and Special Colors |
Specifies the model to use when creating or adjusting a spot color or special color to reproduce the desired color. Select from [X-Rite i1Pro / Pro 2 / Pro 3], [X-Rite i1Pro 3 Plus], [Barbieri Spectro LFP qb Spectral unit], and [Barbieri Spectro pad]. Default value: [X-Rite i1Pro / Pro 2 / Pro 3] |
|||||
For Printer Color Matching |
Specifies the model to use for the printer color match function that matches output colors which are slightly different with each printer. Select either Use For Color Charts or [VW-S1]. Default value: Use For Color Charts |
|||||
Roland@NET | Sets the software update method. | |||||
Check for Updates Automatically and Notify | When this check box is selected, notification of update information is provided. Default value: On |
Performing Updates According to Their Details | ||||
Update Settings | Sets the frequency for acquiring update information. Default value: Every Launch |
|||||
Every Launch | ||||||
Every Day | ||||||
Every Week | ||||||
Every Month | ||||||
Proxy Server | When a proxy server is required in order to connect to the Internet, configure the settings here. Default value: Off |
1. Enter the proxy server settings. | ||||
Use Proxy Server | ||||||
IP Address | ||||||
Port | ||||||
Update Options | Sets the update details. | 2. Set the update details. | ||||
Download Updates for ALL Languages | Select this check box to download updates for all languages (recommended). Default value: On |
|||||
Download Media and Color Profiles | Select this check box in order to select the downloading conditions (recommended). Default value: ALL Available Updates |
|||||
ALL Available Updates | Select this check box to update the data for all printers and all ink configurations supported by VersaWorks (recommended). | |||||
Only for the Current Printer Model in Use | Select this check box to update the data for the printer model that you are currently using and for all ink configurations supported by this model. | |||||
Only for the Current Printer Model and Ink Type | Select this check box to update only the data for the current printer model and ink. | |||||
Multiple Printer Support | Sets the job display and the number of printers where output will be performed simultaneously. | |||||
Layout Window Settings | Displays the jobs for all registered printers in the job list and layout window. Select Show Jobs for Selected Printer Only if the monitor is small and hard to see. Default value: Show Jobs for All Printers |
|||||
Show Jobs for All Printers | ||||||
Use the Same Scale for All Printers | ||||||
Show Jobs for Selected Printer Only | ||||||
Output Settings | Sets the number of printers where output will be performed simultaneously. Default value: 1 |
|||||
Max. # of Concurrent Outputs | ||||||
Linking | Select this check box to link with external applications. Default value: On |
Linking with External Applications | ||||
Link with External Application |