Reducing the UV Lamp Illumination Intensity

Depending on the media, the standard illumination intensity may be too strong, affecting the printing quality. Additionally, there are printing methods where it is desirable to not cure the ink, allowing for decoration. This section explains how to configure the settings to reduce the illumination intensity of the UV lamp in these situations.

If you change Media Type, Print Quality, Resolution, or Mode after configuring settings, set the illumination intensity again.

Depending on the model you are using, this setting may be disabled.

Procedure
  1. Perform the operation shown below according to what is being set.
    • Job: Double-click the job to open the Job Settings window.
    • Queue folder: Click for the queue folder to open the Queue Properties window.
  2. Click .
  3. Select the Change UV Lamp Illumination Intensity check box in UV Lamp Control.
  4. When a window warning you about changing the illumination intensity appears, click OK.
  5. Set the Illumination Intensity.
  6. Click OK.
    • Any changes made in Job Settings will be applied.
    • When changes are made in Queue Properties:
      1. A message that printing settings will be overwritten appears. Click Yes.
      2. To apply the changes to a job already in the queue folder, select the job and click 1_2_2_4_clear_a.