101D-01** The % milling bur cannot be released. It might be broken from the root.

% indicates a milling bur stocker number from 1 to 16.

Situation/Error Cause 1
The milling bur may be broken from the root due to use exceeding its service life.
Procedure
  1. Hold down the touch sensor on the built-in panel.
    This will clear the error.
  2. Carry out Forced tool release in VPanel.
    The collet will open.
  3. Remove the milling bur.
  4. Clean the ATC magazine.
Situation/Error Cause 2
The milling conditions may be excessively strict.
Procedure
  1. Hold down the touch sensor on the built-in panel.
    This will clear the error.
  2. Review the CAM settings and the shape specified in the CAD data.
If the Error Occurs Again
The collet may be deformed. In this case, replace the collet.Replacing Consumable Parts