Cleaning the Bowl

The regulator is equipped with a filter that becomes filled with drainage (moisture and dust) over time. When a certain amount of drainage collects, it drains automatically from the drain hose, but dirt remains inside the bowl ().

In the following situations, remove the bowl from the regulator and clean the bowl.

  • When drainage remains in the bowl.
  • When the inside of the bowl is dirty.
DWX-53DC_ReguratoreCleaning
WARNING

Be sure to bleed off the air pressure before removing the regulator bowl.

Failure to do so may result in a rupture or components flying off.

WARNING

Before removing or attaching the regulator and before performing maintenance, make sure that the bowl is securely attached.

If the bowl is not properly attached, it may come flying off when compressed air is supplied.

WARNING

Clean the regulator bowl using a neutral detergent. Never use solvents such as gasoline, alcohol, or thinner.

Using solvents may degrade the bowl and may result in a rupture.

Required item
DWX-53DC_TorkDriver_ForTable
Torque screwdriver (0.6 N·m)
Procedure
  1. Stop the supply of compressed air.
  2. Use a torque screwdriver to loosen the screws in the two locations shown in the following figure by about three turns.
    DWX-53DC_ReguratoreCleaning_2
  3. Remove the regulator.
    DWX-53DC_ReguratoreCleaning_3
  4. Remove the bowl from the regulator.
    DWX-53DC_ReguratoreCleaning_4
  5. Wash the bowl using a neutral detergent.
  6. After making sure that the bowl is completely dry, attach the bowl to the regulator.
    DWX-53DC_ReguratoreCleaning_5
  7. Attach the regulator to the machine.
  8. Use a torque screwdriver to tighten the screws in the two locations shown in the following figure.

    Tighten the screws until turning the handle of the torque screwdriver no longer turns the screw bit.

    IMPORTANT Be sure to use the 0.6 N·m torque screwdriver sleeve. Failing to do so may cause the regulator to come loose from the machine, damaging it and injuring the operator.
    TorqueDriver_Sleeve_06Nm
    DWX-53DC_RegulatorCleaning_2-1
  9. Resume the supplying of compressed air.