Cleaning the Coolant Nozzles

Procedure
  1. Show VPanel.
  2. Open the Milling area cleaning window.
    1. In the top window of VPanel, select the machine to operate.
      When you have connected multiple machines, you can switch to a different machine to operate by clicking its image under MACHINE STATUS.
    2. Click Icon_VPanel_CleaningMillingArea.
      The Milling area cleaning window is displayed.
    VPanel_Main_Cleaning
  3. Click Front.

    The rotary axis unit moves to the front of the machine and the spindle head moves to the left side of the machine.

    VPanel_DWX-43W_Cleaning_Front
  4. Open the front cover.

    Hold the parts shown in the figure with both hands and open the cover.

    DWX-43W_main_10
  5. Use the nozzle cleaner to clean all coolant nozzles.
    CAUTION

    Be careful of the pointed portion inside the front cover.

    There is a pointed portion inside the front cover. Exercise caution when cleaning.

    DWX-43W_cleaning_coolant_nozzle_01
  6. When you have finished cleaning, close the front cover.
  7. Click Close.