Filling the Coolant Tank
Do not overfill or tilt the coolant tank.
The fluid inlet on the coolant tank is open. Overfilling or tilting will cause fluid to spill out.
When raising or lowering the coolant tank, hold the parts indicated in the following figure.
Failing to do so may result in your fingers being pinched, leading to injury.
When to Perform This Work
- When first using the machine
- When starting to use the machine again with the tank empty
- When the fluid level in the tank reaches the "MIN" label
When the milling time or usage time exceeds a fixed period, a message is displayed in VPanel.
Replace the coolant according to the instructions displayed in VPanel.
Replacing the CoolantItems to Prepare Yourself
- Water (soft or purified water)
-
Use soft or purified water. Using hard water may have a negative effect on the service life of the milling bur and on the quality of the product.
- Additive (ZAW-1000D)
-
You will need to prepare the designated additive separately. Contact your authorized DGSHAPE Corporation dealer to purchase items.
- Chelating reagent (ZCH-250D)
-
You will need to prepare the designated chelating reagent separately. Contact your authorized DGSHAPE Corporation dealer to purchase items.
Handling Additives
- Store additives in a cool, dark place.
- Due to the characteristics of the internal components, the color may change and deposits of separated components may form, but these do not indicate any problems with the use of the additives.
- If component deposits form, lightly shake the container to mix the components before use.