Step 1: Removing the Coolant Tank

MEMO

When filling the coolant tank, if the fluid level reaches the "MIN" label, no operation is necessary in VPanel.

In this situation, make the coolant according to Step 4 in Step 3: Filling the Machine with New Coolant, and then fill the coolant tank.

Procedure
  1. Show VPanel.
  2. Open the Coolant replacement and cleaning window.
    1. In the top window of VPanel, select the machine to operate.
      When you have connected multiple machines, you can switch to a different machine to operate by clicking its image under MACHINE STATUS.
    2. Click Icon_VPanel_for_DWX_Coolant_replacement.

      The Coolant replacement and cleaning window is displayed.

      VPanel_DWX-43W_CoolantTank_01
  3. Open the front cover.

    Hold the parts shown in the figure with both hands and open the cover.

    DWX-43W_main_10
  4. Remove the workpiece, rotary axis correction jig, and ATC magazine correction jig.
  5. Click Next.
  6. Gently push the bottom cover, and then lower it toward you to open it.
    DWX-43W_coolant_11
  7. Remove the coolant tank.
    MEMO Move the coolant tank slowly. Forcefully moving the coolant tank may cause the coolant to spray out.
    DWX-43W_coolant_01
    CAUTION

    When removing the coolant tank, hold the handle as shown in the figure.

    Placing a finger under the drawer may lead to injury due to your finger hitting the cover.

    DWX-43W_pullout _coolant_caution