5. Configure settings to match the media.
To ensure the optimal output according to the media size and type, set the minimal amount of items. All items set here can be set individually as well.
- On the Select Media Output Type screen, select the output type and tap Next.
- Print Only/Print & Cut
Proceed to step 2.
- Cut Only
Switch to the Multi Sensor Adjustment screen. When automatic adjustment is finished, tap OK. This completes the settings for Cut Only.
- Print Only/Print & Cut
- On the Heater Temperature screen, adjust the Print Heater and Dryer temperatures.
- If this is not necessary, tap Next.
- Follow the procedure below to make changes.
- Tap or to set the Print Heater or Dryer temperature.
- Tap Next.
- Use the Print Head Height screen to adjust the print head height.
- If this is not necessary, tap Next.
- Follow the procedure below to make adjustments.
- Tap Change
- Open the front cover.
- Move the height-adjustment lever to adjust the head height.
- Close the front cover.
- Tap OK.
- Tap Next.
- On the Nozzle Drop-out Test screen, configure the Printing Test and Output Start Location settings.
- If this is not necessary, tap Next.
- To perform a Printing Test, tap . For details on what to do after the printing test, refer to Step 2: Normal Cleaning Method.
- On the Select Media Adjustment Method screen, select the adjustment method.Here, the media feed correction for reducing horizontal bands and the correction of the landing position of the ink will be adjusted.MEMO Simple Correction (Auto) is the recommended adjustment. You can determine the correction values with Detailed Correction (Manual).
- Follow the procedure below to make automatic adjustments.
- Tap .
- Tap Execute on the Batch Automatic Correction screen.
On successful completion of automatic adjustment, the home screen appears. This completes the settings.
For more information, refer to Automatically Making Required Adjustments.
- Follow the procedure below to make manual adjustments.
- Tap .
- Tap Execute on the Multi Sensor Adjustment screen.
Adjust the reading sensor to the optimal condition. If the adjustment failed, respond to the failure according to the information in Correcting the Reading Sensor.
- Tap Next.
- Perform a printing test on the Detailed Feed Correction (Manual) screen.
Set the correction value from the printing test result. For more information, refer to Manual Adjustment: Reducing Horizontal Bands (Feed Correction Function).
- Tap Save and Proceed.
- Perform a printing test on the Detailed Media Gap Adjustment (Manual) screen.
Set the correction values from the printing test result. For more information, refer to Manual Adjustment: Adjusting the Misalignment of the Ink Landing Position (Media Gap Adjustment).
- Tap Save and Exit.
- Follow the procedure below to make automatic adjustments.
When printing and cutting or just cutting, rewind the media from the take-up device to slacken the media.
If sufficient media is not wound on the paper tube immediately after setup, this operation may not be performed well, lowering the cutting quality and preventing continued take-up. When performing cutting immediately after attaching the media to the paper tube, first feed enough media to carry out take-up a few times and set the base point.