Step 1: Cleaning All Print Heads

Procedure
  1. Press [MENU].
  2. Press [▼] several times to display the screen shown below.


  3. Press [▶].
  4. Press [▼] several times to display the screen shown below.


  5. Press [▶] once, and then press [▼] several times to display the screen shown below.


  6. Press [ENTER].
    The screen shown below appears.


  7. Make sure the cleaning liquid is ready.
  8. Press [ENTER].
  9. When the following screen is displayed, open the panel cover.
    Remove the screw on the top of the panel cover, tilt the panel cover forward slightly, and then pull out the panel cover in the direction indicated by the arrow.




  10. Remove the drain bottle and discard the discharged fluid.
    IMPORTANT:
    When you remove the drain bottle, a few drops of discharged fluid may come out of the machine. Exercise caution to prevent this fluid from soiling your hands.
    • Round drain bottle
    1. While supporting the drain bottle, turn it in the direction shown in the figure.
    2. Detach the drain bottle.


    : Upper limit. Discard the discharged fluid before this line is passed.
    • Square drain bottle
    1. Push down on the opening of the drain bottle.
    2. While pushing down on the opening, slide the bottle to the front, ensuring that the bottle stays on the bottom plate.
      Tilting the drain bottle too much to the point that it comes free of the bottom plate may lead to discharged fluid spilling out.
    3. Detach the drain bottle.


    IMPORTANT:
    Tilting the drain bottle too much may lead to discharged fluid spilling out. Slide the drain bottle while ensuring that it stays on the bottom plate.


  11. Wipe away any discharged fluid that has dripped onto the outside of the drain bottle.
  12. Install the drain bottle. (Round drain bottle)
  13. Use tape to fix in place the moving parts (A and B) on the installation unit of the drain bottle. (Square drain bottle)


  14. For the LEF2-300D, remove the spacer table.
  15. Close the panel cover.
    Catch the panel cover pins on the notches, and then attach the panel cover.


    IMPORTANT:

    The following operations will discharge large amounts of fluid. If you do not empty the drain bottle, the discharged fluid may overflow.

  16. Press [ENTER].
    The screen shown below appears.


  17. Thereafter, follow the on-screen instructions to carry out the operations.
    After cleaning has finished, the sub power is automatically switched off.