2. Setting the Air Pressure

MEMO When CAM data is received by the machine, it automatically adjusts the air pressure to match the workpiece to mill.
Procedure
  1. Pull up on the upper knob (the air pressure adjustment knob) ().
    Pressure_ADJ
  2. Adjust the air pressure.
    1. Slowly turn the upper knob to adjust the air pressure to 0.3 MPa.
    2. Slowly turn the upper knob to increase the air pressure to 0.4 MPa.
    WARNING

    Turn the air pressure adjustment knob slowly and carefully.

    Otherwise, the machine may move suddenly, posing a risk of injury.

    IMPORTANT Be sure to adjust the air pressure setting to 0.4 MPa. An air pressure higher than 0.4 MPa may result in a malfunction. If the pressure is too low, the desired results will not be obtained.
    Pressure_ADJ2
    • : Increase the pressure.
    • : Decrease the pressure.
  3. Push down on the upper knob.