2. Setting the Air Pressure
MEMO When CAM data is received by the machine, it automatically adjusts the air pressure to match the workpiece to mill.
Procedure
- Pull up on the upper knob (the air pressure adjustment knob) ().
-
Adjust the air pressure.
- Slowly turn the upper knob to adjust the air pressure to 0.3 MPa.
- Slowly turn the upper knob to increase the air pressure to 0.4 MPa.
WARNINGTurn the air pressure adjustment knob slowly and carefully.
Otherwise, the machine may move suddenly, posing a risk of injury.
IMPORTANT Be sure to adjust the air pressure setting to 0.4 MPa. An air pressure higher than 0.4 MPa may result in a malfunction. If the pressure is too low, the desired results will not be obtained. - Push down on the upper knob.