Manual Adjustment: Adjusting the Misalignment of the Ink Landing Position (Media Gap Adjustment)
First, print a test pattern, and then determine and enter the correction value. After entering the correction value, print a test pattern again and check the correction results.
This adjustment must be performed in the following cases.
-
When using this machine for the first time
-
When changing the media to use
MEMO
Use the following link to view a reference video for this procedure. We recommend that you view this video to understand the overall flow of work.
https://youtu.be/VzQH-mLgvm0Procedure
- Set up the media.
- Close the front cover.
- Click .
- Click Execute under .
-
Click Execute.
Printing of the test pattern starts.
-
Check the printed test pattern, and then enter the No. 1: H1 and H2 and the No. 2: H1 and H2 correction values.
Select the value that gives the least misalignment between the two lines. In the case of the following figure, select "+5" for H1 and "+4" for H2. When you cannot choose between two sequential numbers, select a value that is between them (you can set correction values in units of "0.5").MEMO
- If the test pattern is difficult to see, click or next to Move to move the media to a position where it is easier to see.
- If you want to hold the media to check the test pattern, you can also use the sheet cutting function to separate the media.
-
Click Apply.
The entered correction values are saved.
-
To check the adjustment results, click Output again.
The test pattern is printed again.
-
Check the test pattern to see whether the correction was successful.
For all the correction values, check that the misalignment is minimized for the two vertical lines indicated by "" (that is, the current correction value). If the misalignment is smaller for another set of vertical lines, set the correction value again.
- When you have successfully performed the adjustment, click OK to return to the original screen.