Normal Cleaning

Procedure
  1. Set up the nozzle drop-out test paper.
  2. Click BN2_Utility_Icon_NozzleCleaningCleaning on the Utility home screen.
  3. Select Normal Cleaning under Head Cleaning, and then click Execute.

    Cleaning in progress. and an estimate for the remaining cleaning time are displayed on the Utility home screen.

    Utility_NozzleTest
  4. Click Output under Nozzle Drop-out Test.

    Printing of the test pattern starts.

  5. When printing is complete, open the front cover.
  6. Check whether there is dot drop-out or dot displacement in the test pattern.

    Missing blocks indicate dot drop-out. Collapsed or inclined blocks indicate dot displacement.

    BD-8_TestPrint_Normal
    MEMO
  7. Close the front cover.
    If no dot drop-out or dot displacement occurs, preparations for output are finished.
  8. Click Close to return to the original screen.