Removal
WARNING
Be sure to perform operations as specified by the instructions, and never touch any area not specified in the instructions.
Sudden movement of the machine may cause injury or burns.
WARNING
Only insert and remove the rotary axis unit connector when the main power is off or when executing [Rotary Axis Unit Attachment/Removal] from the Utility.
Failure to do so may result in damage to the equipment or electric shock.
MEMO
-
Use the following link to view a reference video for this procedure. We recommend that you view this video to understand the overall flow of work.
-
Grease may adhere to the rotary axis unit during removal/installation. Use gloves if necessary.
Procedure
- Close the printer's front cover.
-
Press the sub power button on the printer.
The sub power is switched on. When the sub power button indicator changes from flashing blue to steady blue, startup is finished.
-
Start Utility from the Roland DG Connect Hub home screen.
Click Open next to Utility.
-
Click
on the Utility window.
- Click Preferences.
-
Click Execute under .
The flat table moves to a position where the rotary axis unit can be removed.
-
After the flat table stops, open the front cover.
-
Open the maintenance cover according to the procedure below.
-
Remove the connector for the machine.
Press down on the metal part at both ends of the connector to remove it, as shown in the figure.
-
Remove the machine from the flat table.
CAUTION
Exercise caution to prevent the rotary axis unit from falling.
Failure to do so may result in injury.
-
Attach the maintenance cover according to the following procedure.
- Close the front cover.
-
Click Finish on the Utility window.
The illustration on the Utility window will change to the flat table.