Removal

WARNING

Be sure to perform operations as specified by the instructions, and never touch any area not specified in the instructions.

Sudden movement of the machine may cause injury or burns.

CAUTION

To prevent damage to the device and electrical shock, only insert and remove the rotation shaft unit connector when the main power is off or when executing [Insert/remove optional unit] from the utility.

MEMO

Use the following link to view a reference video for this procedure. We recommend that you view this video to understand the overall flow of work.

https://youtu.be/g5oVgQ9NXdI

Procedure
  1. Close the printer's front cover.
  2. Press the sub power button on the printer.
    BD-8_SubPowerON
    The sub power is switched on. When the sub power button indicator changes from flashing blue to steady blue, startup is finished.
  3. Start Utility from the Roland DG Connect Hub home screen.
    Click Open next to Utility.
    BD-8_Utility_Open
  4. Click BD-8_Utility_MenuButton on the Utility window.
    BD-8_Utility_Menu
  5. Click Preferences.
  6. Click Execute under Rotary Unit Attachment/Removal.
    The flat table moves to a position where the rotary axis unit can be removed.
  7. Open the front cover.
    Cover_open
  8. Open the maintenance cover according to the procedure below.
    1. Hold the underside of the maintenance cover, and pull it approximately 30 mm (1.18 in.) towards you.
    2. Lift the maintenance cover up to remove it.
      BD-8_RemoveMaintenanceCover
  9. Remove the connector for the machine.
    Press down on the metal part at both ends of the connector to remove it, as shown in the figure.
    Connecter_Remove
  10. Remove the machine from the flat table.
    CAUTION

    Exercise caution to prevent the rotation shaft unit from falling.

    Failure to do so may result in injury.

    1. Remove the rotary axis unit fixing screws.
      FixedScrew_Remove
    2. Remove the machine from the flat table.
    3. Remove the rotary axis unit positioning screws.
      PositionScrew_Remove
    4. Attach the rotary axis unit fixing screws and rotary axis unit positioning screws to the machine.
      The rotary axis unit fixing screws and rotary axis unit positioning screws are needed when attaching the machine. Attach the rotary axis unit fixing screws and rotary axis unit positioning screws to the machine to store them safely.
      BD-8_FixingScrew_Install
  11. Attach the maintenance cover according to the following procedure.
    1. Insert the hooks (B) on the maintenance cover into the grooves on the left and right (A).
    2. Check that the maintenance cover is fixed in place using the magnets (C).
      BD-8_InstallMaintenanceCover
  12. Close the front cover.
  13. Click Finish on the Utility window.
    This completes the procedure for removing the machine.