Ink Circulating Method

If uneven color issues with white ink are not resolved even after shaking the ink cartridges to mix the ink, perform Ink Circulation. Uneven colors refers to the symptom of printed colors being uneven (such as the color density being inconsistent) even when the same data is printed with the same settings.
MEMO

If the object to be printed on is set up before Ink Circulation is performed, After ink circulation, perform a printing test. will be displayed on the Ink Circulation menu screen. When this setting is turned on, Printing Test will be performed after Ink Circulation even if Nozzle Drop-out Test is not performed.

Note that After ink circulation, perform a printing test. is not displayed if a rotary axis unit is attached.

Procedure
  1. Tap AP-640_Panel_Icon_MENU.
  2. Tap Maintenance - Ink Circulation.
  3. Tap Execute.

    Depending on the timing with which the Ink Circulation is started, cleaning may start. When cleaning is complete, Ink Circulation will start.

    If uneven output color issues with white ink are not resolved even after performing Ink Circulation, perform Powerful Cleaning.

    INK_Circulation
  4. Tap AP-640_Panel_Icon_HOME to return to the home screen.