Alarm Lamp Connector

Pin assignment

CN Signal name Details


+24 V Power supply for the light, 50 mA max.


ERROR MotorError, ProtectMotorError, or temperature error.


READY Setup is complete and printing can start. When flashing, printing is paused.


BUSY Printing.

* Off: This indicates the standby status, warning status, or a similar status. The machine cannot start printing when it is in this status.

Connector assignment



Output specifications

Power supply +24 V (150 mA)
Output Open collector
Output capacity 50 mA max.

Connect the lamp between the 24 V power supply () and (), (), and ().