Compressor (Source of Compressed Air)

This machine requires compressed air. You will need to prepare a compressor separately.

IMPORTANT

Even when it is on standby, this machine periodically uses compressed air.

To allow for compressed air to be supplied, leave the compressor on whenever this machine is on.

WARNING

The pressure of the compressed air must be 1.0 MPa or less.

Anything higher may result in a serious accident such as a rupture.

WARNING

Ensure that the supplied compressed air is not contaminated by water, oil, chemicals, or foreign objects.

The components may deteriorate or rupture, or the contaminants may be scattered, posing a hazard.

WARNING

Supply the compressed air after the air hose is connected securely.

Doing so may cause an accident.

The compressor must meet the following conditions.

  • Control pressure: 0.25 MPa or more
  • Air capacity: 39 l/min or more (per machine)
  • Oil-free type (To prevent contamination of the compressed air by foreign material.)
  • Dryer-equipped (To prevent moist air that can cause rust.)