Step 3: Printing Tests and Normal Cleaning
Procedure
- Open the Utility window.
-
Click Check Nozzle Condition.
-
Click Test Print.
The test pattern is printed. Follow the on-screen instructions and check for dot drop-out.
- Nozzle clogging occurs -> Proceed to 4
- Nozzles are not clogged -> Click Close.
-
Select Normal Cleaning and click Go.
Normal cleaning starts.
-
To check for nozzle clogging again
If the nozzle clogging is not fixed, perform Normal Cleaning again. For information about Medium Cleaning and Powerful Cleaning, refer to the following topic.