3. Perform a printing test to check the results.

Procedure
  1. Load the media.
  2. Press [FUNCTION].
  3. Press [▼], then [▶] to display the screen shown below.


  4. Press [ENTER].
    Printing of the test pattern starts.
  5. Check whether there is dot drop-out or dot displacement in the test pattern.
    Missing blocks indicate dot drop-out. Collapsed or inclined blocks indicate dot displacement.


  6. If you have opened the front cover, close it.
    If no dot drop-out or dot displacement occurs, this operation is finished. Press [FUNCTION] to go back to the original screen.

If the dot drop-out or dot displacement location is different, perform medium cleaning another two or three times. If dot drop-out or dot displacement occurs in the same location on the test pattern, contact your authorized Roland DG Corporation dealer.