Emergency Measure) Cleaning the Print Head Surface
This operation is an emergency measure. It may damage defect-free parts depending on the symptoms, worsening the symptoms. If you have any questions, contact your authorized Roland DG Corporation dealer.
Procedure
- Apply a large amount of cleaning liquid to the cleaning stick.
- Very gently touch the cleaning stick against the print head surface (nozzle surface).Very softly press the cleaning stick against the print head so that cleaning liquid soaks into the print head surface (nozzle surface). Never rub the stick on the surface or press it forcibly.