If the Drain Bottle Exceeds Its Capacity Limit (Square Drain Bottle)

The drain bottle collects discharged fluid. If you continue to use the drain bottle without discarding the discharged fluid even though the message "EMPTY DRAIN BOTTLE" has been displayed, the drain bottle will become full, and the message shown below will be displayed. No more discharged fluid can be stored in the drain bottle, so be sure to discard the discharged fluid immediately. If this message appears during printing, printing is stopped.


IMPORTANT:

When the message [LIMIT OVER EMPTY DRAIN BOTTLE] is displayed on the screen, be sure to discard the discharged fluid.

If you do not discard the discharged fluid, you will not be able to clear this message.

Procedure
  1. When the following screen is displayed, open the panel cover.
    Remove the screw on the top of the panel cover, tilt the panel cover forward slightly, and then pull out the panel cover in the direction indicated by the arrow.




  2. Remove the drain bottle and discard the discharged fluid.
    IMPORTANT:
    When you remove the drain bottle, a few drops of discharged fluid may come out of the machine. Exercise caution to prevent this fluid from soiling your hands.
    1. Push down on the opening of the drain bottle.
    2. While pushing down on the opening, slide the bottle to the front, ensuring that the bottle stays on the bottom plate.
      Tilting the drain bottle too much to the point that it comes free of the bottom plate may lead to discharged fluid spilling out.
    3. Detach the drain bottle.


    IMPORTANT:
    • Tilting the drain bottle too much may lead to discharged fluid spilling out. Slide the drain bottle while ensuring that it stays on the bottom plate.


  3. Wipe away any discharged fluid that has dripped onto the outside of the drain bottle.
  4. Quickly attach the drain bottle to the machine once more.
    1. Set the drain bottle in place, and then push down on the opening of the bottle.
    2. While pushing down on the opening, slide the bottle to the back, ensuring that the bottle stays on the bottom plate.


    3. When the drain bottle reaches the wall, remove your hand.
      Point: Push the drain bottle all the way to the back, ensuring that the opening does not get caught on the frame (A).


    4. Check that the drain bottle has been pushed all the way to the back and does not move.
      If the drain bottle is not in the correct position, the drain hose will be misaligned, which may lead to discharged fluid spilling out.
    IMPORTANT:

    If the message "EMPTY DRAIN BOTTLE" is displayed even after you have attached the drain bottle, the drain bottle may not have been set in place correctly.

    Remove the drain bottle, and then attach it again.

  5. Close the panel cover.
    Catch the panel cover pins on the notches, and then attach the panel cover.


  6. Press [ENTER].