1. Attaching the Regulator to the Machine

The regulator can be attached in one of two locations on the machine: the right side (A) or the back (B).

If necessary, remove the stay () before attaching the regulator to the machine.

DWX-53D_regulator_stay

This section explains how to attach the regulator to the right side (A) of the machine with the stay removed.

To attach the regulator to the back (B) of the machine, substitute the attachment position when performing the work.

DWX-53D_regulator_pos
Procedure
  1. Temporarily tighten the two screws (for the regulator) () on the right side of the machine.

    Turn the screws approximately 3 times by hand.

  2. Mount the regulator bracket () onto the screws temporarily tightened in step 1, and then fully tighten these screws with a torque screwdriver.
    IMPORTANT

    Attach the 0.6 N·m, red sleeve onto the torque screwdriver before tightening the screws.

    TorqueDriver_UseSleeve06

    Tighten the screws until turning the handle of the torque screwdriver no longer turns the screw bit.

    Install_Regu
  3. Attach the drain hose () to the regulator bowl ().

    Any fluid that collects in the bowl will drain from the drain hose. Set the fluid receptacle in place.


    ConnectDrainHose
  4. Insert the air hose into the machine.
    WARNING

    Securely insert the air hose as far as it will go. Lightly tug the hose to make sure it does not come loose.

    If it is not inserted securely, it may come loose.

    Attach the air hose included with the machine.


    Hose_ToDWX
  5. While pressing the regulator ring in, insert the air hoses into the regulator.
    WARNING

    Securely insert the air hose as far as it will go. Lightly tug the hose to make sure it does not come loose.

    If it is not inserted securely, it may come loose.

    Attach to the left side of the regulator the air hose () included with the compressor you are using. Attach to the right side of the regulator the opposite side of the air hose () attached to the machine.


    Install_Regu2
  6. Supply compressed air and verify that air does not leak from the connections or any other location.
    MEMO To remove an air hose from the regulator, pull the hose out slowly while pressing the regulator ring in.

    Install_Regu3
    MEMO

    When attaching the regulator to the back of the machine, use the hose clamp attached to the stay to bundle the air hoses together.

    DWX-53D_regulator_hose-clamp