Step 4: Correcting the Media Feed
Procedure
- Open the Utility window.
-
Click Calibrate Sheet Feeding.
-
Click Test Print.
A test pattern is printed.
-
Follow the on-screen instructions and enter the value for New Value.
The current correction value (A) is that of the figure indicated by "
." Select the value to make the gap (B) and overlap (C) between the upper/lower squares smallest. In the case of the following figure, select "−1.05%." When you cannot choose between two sequential numbers, specify a value that is between them.
-
Click Apply.
The value in Current Value changes to the entered value.
- Click Close.