Step 4: Correcting the Media Feed
Procedure
- Open the Utility window.
-
Click Calibrate Sheet Feeding.
-
Click Test Print.
A test pattern is printed.
-
Follow the on-screen instructions and enter the value for New Value.
The current correction value (A) is that of the figure indicated by "." Select the value to make the gap (B) and overlap (C) between the upper/lower squares smallest. In the case of the following figure, select "−1.05%." When you cannot choose between two sequential numbers, specify a value that is between them.
-
Click Apply.
The value in Current Value changes to the entered value.
- Click Close.