Step 4: Correcting the Media Feed

Procedure
  1. Open the Utility window.
  2. Click Calibrate Sheet Feeding.
    BN-20A_UtilityMedFeed
  3. Click Test Print.
    A test pattern is printed.
    BN-20A_UtilityMedFeed_01
  4. Follow the on-screen instructions and enter the value for New Value.
    The current correction value (A) is that of the figure indicated by "Triangle_01." Select the value to make the gap (B) and overlap (C) between the upper/lower squares smallest. In the case of the following figure, select "−1.05%." When you cannot choose between two sequential numbers, specify a value that is between them.
    VG3-Testprint_ShudouOkurihosei
  5. Click Apply.
    The value in Current Value changes to the entered value.
  6. Click Close.