Updater [ 2022-11-08, Ver.1.90 ]

Ver. 1.90 Date: 2022/11/8
[change in spec.]
1. Operation at the time of limit switch detection for X/Y/Z axes has been improved, and detection accuracy will be maintained longer than before.

 

[bug fix] (Following problems have been fixed.)
1. Milling may not start when data is ouput from VPanel for DWX.

2. When a step-out is detected in each axis, an incorrect value is recorded in the log stored in the local file of the PC.

3. When an error 1020/1021-000*/1022-000* occurs, the contents of the log stored in the local file of the PC are not correct.

Note
- If you upgrade the firmware, you need to upgrade VPanel for DWX to v3.16.1 or later at the same time.

 

Ver. 1.80 Date: 2022/5/13
[bug fix] (Following problems have been fixed.)
1. An error may occur when automatic correction is performed with ZS-52D.

2. B-axis Rotary axis travel abgle has been extended from ±30° to ±30.5°.

Note
- If you upgrade the firmware, you need to upgrade VPanel for DWX to v3.16.1 or later at the same time.

 

Ver. 1.70 Date: 2022/1/28
[change in spec.]
1. New spindle unit: ZS-52D has been supported.  

2. Collet is now being kept open if the machine is not grasping a tool. 

3. Maintenance sequence has been changed. (Spindle run-in, Spindle replacement, Open collet, Close collet)

Note
- If you upgrade the firmware, you need to upgrade VPanel for DWX to v3.15.1 or later at the same time. 
 

Ver. 1.50 Date: 2021/7/9
[change in spec.]
1. In order to improve the accuracy of automatic correction, operation sequence has been changed. 
- Referential time for automatic correction has been changed from 10 minutes to 18 minutes.

Note
- You need to perform automatic correction with VPanel for DWX ver. 2.4.4 or later after upgrading the firmware. If you upgrade the firmware from V120 or earlier and then perform milling, [103B-0000] occurs and the message [The automatic correction is not yet finished.] is displayed even if automatic correction was performed.

Ver. 1.40 Date: 2020/5/14
[change in spec.]
1. Log is recorded at the time of the change of a milling bur now.

Note
- You need to perform automatic correction with VPanel for DWX ver. 2.4.4 or later after upgrading the firmware. If you upgrade the firmware from V120 or earlier and then perform milling, [103B-0000] occurs and the message [The automatic correction is not yet finished.] is displayed even if automatic correction was performed.

Ver. 1.30 Date: 2019/6/11
[change in spec.]
1. Air blower and external dust collector will not operate now when a tool is changed during the automatic correction.
2. The sequence of automatic correction has been reviewed, and the milling accuracy has been improved.
- You need to upgrade VPanel for DWX to V2.44 or later at the same time when you upgrade the firmware.
- You need to perform automatic correction with VPanel for DWX V2.44 or later after upgrading the firmware and VPanel for DWX.


Ver. 1.20 Date: 2018/2/1
[change in spec.]
Initial Release