Updater [ 2023-12-27, V260 ]

V260 Date: 2023/12/27

[bug fix] (Following problems have been fixed.)

1. During [collet open], "[EMERGENCY STOP]: 1018-0000 The chucking sensor was not found." may occur even if the machine is operating normally.

 

<Note>

- If you upgrade the firmware, you need to upgrade VPanel for DWX to V4.4.0 or later at the same time.

 

V250 Date: 2023/12/18

[change in spec.]
1. The processing of limit detection has been changed.

2. The collet may not release the milling bar.
3. In DWX-52DCi Plus, the shape of the clamp tip has been changed and the operation sequence has been modified to improve the stability of disc change.

<NOTE>
- VPanel for DWX V4.4.0 or later is required with the upgrade of the firmware version. 

 

V240 Date: 2023/6/12
[change in spec.]

1. [Manual correction] has been added to the [Machine Settings] > [Maintenance] tab in VPanel for DWX. 

- A manual correction function using milling has been added to improve milling quality.

<NOTE>

- VPanel for DWX V4.4.0 or later is required with the upgrade of the firmware version. 

 

V230 Date: 2023/4/5
[change in spec.]
1. Operation at the time of limit switch detection for X/Y/Z axes has been improved, and detection accuracy will be maintained longer than before.  
2. Limit detection accuracy for each axis has been improved.

 

[bug fix] (Following problems have been fixed.)
1. When the tool moves to the home position, the A-axis may collide with the ceiling.

2. Milling may not start when data is ouput from VPanel for DWX.

 

NOTE

- If you upgrade the firmware, you need to upgrade VPanel for DWX to v4.3.0 or later at the same time.

 

V220 Date: 2022/5/20

[bug fix] (Following problems have been fixed.)
1.  When a job is canceled in VPanel for DWX, an error may occur on the machine.
NOTE
-If you upgrade the firmware, you need to upgrade VPanel for DWX to v3.16.1 or later at the same time.

 

V210 Date: 2022/5/12

[change in spec.]
1. New spindle unit: ZS-52D has been supported.  

2. Collet is now being kept open if the machine is not grasping a tool. 

3. Maintenance sequence has been changed. (Spindle run-in, Spindle replacement, Open collet, Close collet)
NOTE
-If you upgrade the firmware, you need to upgrade VPanel for DWX to v3.16.1 or later at the same time.  

 

V200 Date: 2020/9/14

[change in spec.]
1. In order to improve the accuracy of automatic correction, operation sequence has been changed.
    - Referential time for automatic correction has been changed from 10 minutes to 18 minutes.
NOTE
- You need to perform automatic correction with VPanel for DWX V3.3.0 or later after upgrading the firmware. If you upgrade the firmware from Main V. 170 or earlier, and then perform milling, [103B-0000] error occurs and the message [The automatic correction is not yet finished.] is displayed even if automatic correction was performed.


V190 Date: 2020/5/14

[change in spec.]
1. Log is recorded at the time of the change of a milling bur now.

Note
-You need to perform automatic correction with VPanel for DWX V3.3.0 or later after upgrading the firmware. If you upgrade the firmware from Main V. 170 or earlier, and then perform milling, [103B-0000] error occurs and the message [The automatic correction is not yet finished.] is displayed even if automatic correction was performed.

V181 Date: 2019/9/2

[change in spec.]
1. Air blower and external dust collector will not operate now when a tool is changed during the automatic correction.
- This prevents milling waste from scattering, and reduces the risk of coordinates detection failure as a result.
2. The sequence of automatic correction has been reviewed, and the milling accuracy has been improved.
- You need to upgrade VPanel for DWX to V3.3.0 or later at the same time when you upgrade the firmware.
- You need to perform automatic correction with VPanel for DWX V3.3.0 or later after upgrading the firmware and VPanel for DWX.


V180 Date: 2018/11/30

[bug fix] (Following problems have been fixed.)
1. If the motor loses a step during a change of adapter, the machine may not recognize the error for a certain period of time.
2. When you open the magazine cover during spindle run-in, the clamp collides with the milling bur.


V170 Date: 2018/7/23

[bug fix] (Following problems have been fixed.)
1. With the firmware V1.60, the adapter may collide with the top of the cabinet at the start of milling.


V150 Date: 2018/2/14

[bug fix] (Following problems have been fixed.)
1. A-axis limit switch detection error (1000-0008) may occur at the time of origin point detection.
2. If the operation button is held down while the machine is in the maintenance mode, the machine may beep 4 times and the operation may stop. The machine now beeps once, and the operation will not stop.
- Maintenance mode: It is an operational mode of the machine which is processed from [Settings] > [Maintenance] tab in Vpanel.

NOTE
Please upgrade the following two types of firmware.
- Firmware for the main board
- Firmware for the main board for the disc changer


V140 Date: 2017/11/15

[change in spec.]
1. Dust collector turns on automatically now when the front cover is opened after milling is completed.
2. The dust collector can now be turned on/off, by pressing the operation button while the machine is in a paused state with the front cover being open.

[bug fix] (Following problems have been fixed.)
1. Spindle keeps rotating if the operation button is pressed while only magazine cover is open.
2. The adapter may not be returned to the stocker if the operation button is long-pressed while the disc changer is holding the adapter during standby.
3. Closing of collet may fail, and [101A-0000] or [101B-0000] error may occur.
4. Origin point detection may fail if the detection is performed from the reversed position of A-axis.